| General Settings | |
|---|---|
| Language | US English |
| Code summary | Long |
| Trend summary | Off |
| Site number | APPLETON, BOLIVAR, ELDORADO, HERMITAGE, OSCEOLA, or STOCKTON |
| Device ID | match property ID tag |
| Auto log | On |
| Line filter | 60 Hz |
| Timeout speed | 30 sec |
| Manual Mode Settings | |
| Sync after shock | On |
| Pads default | 360 |
| Energy protocol | Inactive |
| Internal default | 10 |
| Voice prompts | On |
| Shock tone | On |
| Manual access | Manual / Direct |
| No passcode required for manual mode | |
| AED Mode Settings | |
| Energy protocol | 360 - 360 - 360 |
| Auto analyze | Off |
| Motion detection | On |
| Pulse check | Never |
| CPR Settings | |
| CPR time 1 | 120 sec |
| CPR time 2 | 120 sec |
| Initial CPR | CPR first |
| Initial CPR time | 120 sec |
| Preshock CPR | Off |
| CPR Metronome Settings | |
| Metronome | On |
| Adult - No Airway | 30 : 2 |
| Adult - Airway | 100 : 0 |
| Youth - No Airway | 15 : 2 |
| Youth - Airway | 100 : 0 |
| Pacing Settings | |
| Rate | 70 ppm |
| Current | 0 mA |
| Mode | Demand |
| Internal pacer | Detection on |
| Monitoring Channels Settings | |
| Default set | Set 1 |
| Set 1 | I, II, CO2 |
| Set 2 | II, SpO2, CO2 |
| Set 3 | I, II, III |
| Set 4 | II, III, aVF |
| Set 5 | aVL, V5, V6 |
| Monitoring Settings | |
| Continuous Data | All Channels |
| SpO2 tone | Off |
| CO2 units | mmHg |
| CO2 BTPS | Off |
| Temperature Units | °F |
| NIBP initial pressure | 160 mmHG |
| NIBP interval | 10 min |
| Trends | On |
| 12-Lead Settings | |
| Auto transmit | Off |
| Auto print | On |
| Print speed | 25 mm/sec |
| Interpretation | Off |
| Format | 3-channel standard |
| Events Pages Settings | |
| 1 | Generic |
| 2 | Medication - Albuterol |
| 3 | Medication - Aspirin |
| 4 | Medication - Atropine |
| 5 | Medication - Benadryl |
| 6 | Medication - Dextrose |
| 7 | Medication - Duoneb |
| 8 | Medication - Cardizem |
| 9 | Medication - Epinephrine 1:10,000 |
| 10 | Medication - Fentanyl |
| 11 | Medication - Glucose |
| 12 | Medication - Morphine |
| 13 | Medication - Narcan |
| 14 | Medication - Nitroglycerin |
| 15 | Medication - Oxygen |
| 16 | Medication - Phenergan |
| 17 | Medication - Solu-Medrol |
| 18 | Medication - Versed |
| 19 | Medication - Xopenex |
| 20 | Medication - Zofran |
| 21 | |
| 22 | |
| 23 | Treatment - Airway insert |
| 24 | Treatment - CPAP |
| 25 | Treatment - Vascular access |
| Alarms Settings | |
| Volume | 5 |
| Alarms | Off |
| VF / VT alarm | Off |
| Auto Print Settings | |
| Defibrillation | On |
| Pacing | Off |
| Check patient | Off |
| SAS | Off |
| Patient alarms | Off |
| Events | Off |
| Initial rhythm | Off |
| Printer Settings | |
| ECG mode | Monitor |
| Monitor mode | 1 - 30 Hz |
| Diagnostic mode | 0.05 - 40 Hz |
| Alarm waveforms | On |
| Event waveforms | On |
| Vitals waveforms | On |
| Transmission Sites Settings | |
| Site 1 | BLUETOOTH Bluetooth Wireless |
| Site 2 | USB Direct Connect |
| Site 3 | CMH BOLIVAR Direct Connect |
| Site 4 | MERCY SGF Direct Connect |
| Site 5 | COX SOUTH Direct Connect |
| Site 6 | LAKE Direct Connect |
| Site 7 | ESO Direct Connect |
| Transmission Settings | |
| Default Site | ESO |
| Default Report | All |
| Wireless | On |
| Search Filter | Off |
| Clock Settings | |
| Clock Mode | Real Time |
| Time Zone | UTC -06:00 |
| Date | Link topreviousversion | Description of change |
|---|---|---|
| 07/23/19 | Added standardized programming for LifePak into protocol for medical director approval. | |
| 08/07/20 | Added content (without substantive modification) from old Section 8-190 - LifePak. | |
| 06/11/21 | Moved to emsprotocols.online |
Return to Protocols Table of Contents.
| CMH Pre-Hospital Services Mission: "Provide safe, exceptional, and compassionate care to our communities with an emphasis on highly trained and empowered staff." | CMH Mobile Integrated Healthcare Mission: "Provide exceptional, compassionate, and patient-centered care by a mobile collaborative team to improve patient experience, improve quality outcomes, and reduce healthcare costs." |
|
![]() |
Polk, Hickory, Cedar, & St Clair County EMS Protocols is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License. |